top of page

Richter Rubber Technology

WARRANTEE PERIOD

One year–not including normal wear and tear on parts like bearings, brushes, belts etc.

OPTIONALLY AVAILABLE

 

  • Double screening system for condoms with the installation of two scanners, doubling scanning time and improving pinhole detection reliability by 100%.

  • High voltage generator ensuring stepless regulation of scanning voltage up to 3000V. 

  • Option for two high voltage generators to independently regulate scanning voltage on each scanner or both the top and bottom of each scanner, up to 3000V. 

  • Software and interface provided for connecting a single PC to facilitate comprehensive data collection. 

  • No restrictions on the number of machines that can be used. 

  • All data integration facilitated by a chip situated on the main board of the ET electronic.

TECHNICAL DATA

Capacity

Operator

Power Supply

Compressed Air

Weight

Dimensions

(length x width x height)

76 to 88 PCs./ min mechanically adjustable

2 operators

380/400V 3 phase, 50/60Hz, c. 0.9 kW

6 bar oil and water free c. 2 m³/h

approx. 430kg

1.55m x 1.25m x 1.10m

Capacity

76 to 88 PCs./ min mechanically adjustable

 

Operator
2 operators


Power Supply
380/400V 3 phase, 50/60Hz, c. 0.9 kW


Compressed Air
6 bar oil and water free c. 2 m³/h


Dimensions
(length x width x height)

1.55m x 1.25m x 1.10m

Weight

approx. 430kg

DESCRIPTION
  • Two autonomous testing/operating stations, each with a production rate of 38-45 pcs/min, featuring adjustable speed via an inverter and equipped with a safety switch-off mechanism when stationary.

  • The machine's total nominal output is 220-250 units per 8-hour shift, operated by two individuals.

  • On each side's turntable, there are six aluminum mandrels tailored to customer specifications, with the option for Stainless Steel.

  • Condoms undergo testing, rolling up, and separation into good or reject categories, then collected in separate bins.

  • The machine incorporates a secure roll-up and keep-in-place system.

  • Utilizes a newly developed electronic system with testing voltage up to 3,000V and an enhanced scanning system.

APPLICATION

The machine is designed for the screening of condoms, identifying thin spots and pinholes through high-voltage dry processes. It then proceeds to roll up the condoms and sort them into categories of accepted and rejected items.

Richter Engineering's Electronic Testing Machine

High Voltage Dry Electronic Screening and Rolling Machine

bottom of page